<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-14 10-30-38
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
87.90 MHz 5/5, 52 dBuV R-VYSOC
Pilot RDS Phase Difference
0.0 kHz 3.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
4 kHz 35 kHz 19019 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-3,4 dBr -1,62 dBr -0,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-VYSOC " 2D09 9 (Varied) 1 0 1 1 10:30, 14.12.2025
RT
"Cesky rozhlas Vysocina - zijeme tu s vami "
AF EON
87.9, 90.1, 96.5 MHz -
FM Scope Max at: 35 kHz MIN: 4 kHz % above 77 kHz: 0,0000 Acquired: 2025/12/14 10:30:35 Total samples: 19019 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,5 dBr MIN: -3,4 dBr AVE: -1,62 dBr % above 0,2 dBr: 0,0 Last value: -2,4 dBr (2025/12/14 10:30:34) 10:16 10:18 10:20 10:22 10:24 10:26 10:28 10:30 0 50 100 Dev. MAX [kHz] -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality